Sequence Smarter. Discover More.
Sequencing and bioinformatics from genomics experts
Full Flow Cells & Bulk Sequencing Services
Sequencing and bioinformatics from genomics experts
Short Read Bulk Sequencing- Illumina
| Flow Cell Type | Read Qty. | Read Length | Cycle Qty. | Data Volume | 
|---|---|---|---|---|
| P1; Illumina short read | 100M single-end or 200M paired-end | 100 bp | 100 cycles | 10 Gb | 
| 300 bp | 300 cycles | 30 Gb | ||
| 600 bp | 600 cycles | 60 Gb | ||
| P2; Illumina short read | 400M single-end or 800M paired-end | 100 bp | 100 cycles | 40 Gb | 
| 200 bp | 200 cycles | 80 Gb | ||
| 300 bp | 300 cycles | 120 Gb | ||
| P2; Illumina short read | 300M single-end or 600M paired-end | 600 bp | 600 cycles | 180 Gb | 
| P3; Illumina short read | 1.2B single-end or 2.4B paired-end | 50 bp | 50 cycles | 60 Gb | 
| 100 bp | 100 cycles | 120 Gb | ||
| 200 bp | 200 cycles | 240 Gb | ||
| 300 bp | 300 cycles | 360 Gb | ||
Submission Requirements
- Read configuration desired- e.g. 2x150bp paired end reads
- Read Lengths listed here represent the maximum read length for each configuration. This can be customized if you need a specific read length!
 
- Multiplexing strategy- List of indexes used, unique dual vs combinatorial, etc.
 
- Whether PhiX spike-in is needed- We recommend 35-40% PhiX for low-diversity library pools
 
- Confirm that custom sequencing primers are not needed for the NextSeq2000
Service Includes
- QC of your sample via Qubit and Tapestation
- Dilution to loading concentration
- Demultiplexing analysis using the customer provided data sheet
- Data delivery within 14 business days- Complete Illumina sequencing output with sequencing stats and summary
- Fastq files for individual samples according to customer-provided demultiplexing key
- Materials and methods summary
 
Sample Requirements
- Prepared and pooled libraries with a final concentration of at least 2 nM
Optional Add-Ons
- DNA extraction
- Library prep
- Library pooling
Long Read Bulk Sequencing - Nanopore
| Flow Cell Type | Read Length | Data Volume | 
|---|---|---|
| GridION | Read length is highly variable and dependent on high quality sample input. We offer DNA extraction services using workflows designed to maximize fragment length and quality from diverse sample types. | Typical output between 10-20 Gbp | 
| PromethION | Typical output between 60-120 Gbp | 
Submission Requirements
- Whether native ligation or rapid transposase PCR-free library prep should be used
Service Includes
- QC of your sample via Qubit and Tapestation
- PCR-free library prep for one sample- Native ligation or rapid transposase
 
- Data delivery within 14 business days- One fastq file per sample
- Fast5 files with kinetic data
- Sequencing stats and summary
- Materials and methods summary
 
Sample Requirements
- Total sample volume of >60 µL at a concentration of at least 50 ng/µL
Optional Add-Ons
- DNA extraction
- Additional library preps
- Adaptive sampling methods to enrich coverage in regions of interest
Contact us to get a custom quote for high volume sequencing.
Not sure where to start? Our consultation services provide expert advice tailored to your project’s needs.
